ANALISIS PERFORMA COOLING TOWER JENIS INDUCED DRAFT COUNTER FLOW DI POWER PLANT

Authors

  • Jhon Hericson Purba Program Studi Teknologi Rekayasa Pembangkit Energi, Politeknik Negeri Batam
  • Alfina Syaputri Program Studi Teknologi Rekayasa Pembangkit Energi, Politeknik Negeri Batam

DOI:

https://doi.org/10.30871/jatra.v7i2.10911

Keywords:

Cooling Tower, Efficiency, Make Up Water, Cooling Capacity

Abstract

The cooling tower is a crucial component in the water cooling system of a power plant. During its operation, the cooling process occurs when the water entering the cooling tower undergoes heat transfer through direct contact with cool air, resulting in evaporation. This process leads to water losses in the form of evaporation loss and blowdown, which affect the cooling capacity of production equipment. This study aims to analyze the performance of an induced draft counter-flow cooling tower at PT. X by examining parameters such as range, approach, cooling effectiveness, evaporation loss, and cooling capacity. The results indicate that the cooling tower operates with a range of 6.03°C, an approach of 4.4°C, a cooling effectiveness of 58.75%, a make-up water rate of 43.07 m³/h, and a cooling capacity of 29,419.58 kW. A strong correlation (0.958) between inlet and outlet water temperatures demonstrates consistent heat transfer performance. The system shows improved performance, with ΔT increasing from 2.78°C in 2015 to 6.44°C in 2024. Based on the analysis, it can be concluded that the cooling tower remains feasible for operation but requires regular maintenance to optimize performance.

Downloads

Download data is not yet available.

References

[1] E. T. Budisantoso, Suprapto, and Sutadi, “Kinerja instalasi pendingin siklotron decy-13,” Pros. Pertem. dan Present. Ilm. Teknol. Akselerator dan Apl., vol. 17, no. November, pp. 50–55, 2015.

[2] Firman Manahan Panjaitan and I. Z. Putra, “Analisis Pengaruh Temperatur Ambient Terhadap Kinerja Cooling tower Unit 2 Berdasarkan Evaluasi Range dan Approach pada PLTGU PT Mitra Energi Batam,” J. Integr., vol. 17, no. 1, pp. 32–39, 2025, doi: 10.30871/ji.v17i1.9344.

[3] L. P. I. Midiani, I. W. Temaja, I. P. M. Adnyana, I. K. Dwiana, and I. M. P. Yoga, “Analisa kinerja cooling tower tipe counter flow induced draft,” J. Appl. Mech. Eng. Green Technol., vol. 2, no. 2, pp. 72–77, 2021, doi: 10.31940/jametech.v2i2.2712.

[4] Y. Cui, L. Xia, Y. Huang, and X. Ma, “Research on Fault Diagnosis and Early Warning of Power Plant Boiler Reheater Temperature Deviation Based on Machine Learning Algorithm,” in 2020 IEEE 6th International Conference on Control Science and Systems Engineering (ICCSSE), 2020, pp. 212–216, doi: 10.1109/ICCSSE50399.2020.9171950.

[5] S. Wahyu, A. Mustain, and M. A. Rizky, “Analisa Perhitungan Efisiensi Cooling tower 32 T 821 Pada Utilitas Ii Produksi Ii B Pt Petrokimia Gresik,” DISTILAT J. Teknol. Separasi, vol. 9, no. 1, pp. 114–119, 2023, doi: 10.33795/distilat.v9i1.520.

[6] D. Eswaravelu and I. M. Said Al-Maashani, “Thermodynamic Analysis of Cooling tower Performance in Dhofar Region Power Plants,” in 2024 2nd International Conference on Computing and Data Analytics (ICCDA), 2024, pp. 1–6, doi: 10.1109/ICCDA64887.2024.10867298.

[7] M. A. A. J, A. Asrina, A. Ardiansah, and I. Nuhardin, “Evaluasi Kinerja Cooling tower Type Induced Draft Counter Flow Pada Sirkulasi Air Jernih Industri Baja,” J. Chem. Process Eng., vol. 9, no. 1, pp. 1–10, 2024, doi: 10.33096/jcpe.v9i1.732.

[8] R. V. D. P.E and M. S. P.E, “Improving Cooling Performance of Gas Conditioning Towers/Downcomers to Reduce Plant Emissions,” in 2021 IEEE-IAS/PCA Cement Industry Conference (IAS/PCA), 2021, pp. 1–4, doi: 10.1109/IAS/PCA50164.2021.10143789.

[9] J. Amin, H. Li, Y. Zhiqiang, J. Li, G. Yin, and Z. Qinggang, “Experiment Study on Tower Cooling Energy-Saving Technology,” in 2011 International Conference on Computer Distributed Control and Intelligent Environmental Monitoring, 2011, pp. 728–730, doi: 10.1109/CDCIEM.2011.582.

[10] A. S. Anugrah, F. A. Firmansyah, R. A. Ilhamsyah, and M. F. Umam, “Analisis Kinerja Natural Draft Cooling tower di Unit Kilang Pusat Pengembangan Sumber Daya Manusia Minyak dan Gas Bumi,” Maj. Ilm. Swara Patra, vol. 11, no. 1, pp. 1–13, 2021, doi: 10.37525/sp/2021-1/270.

[11] M. Rahmati, S. R. Alavi, and A. Sedaghat, “Thermal performance of natural draft wet cooling towers under cross-wind conditions based on experimental data and regression analysis,” in 2016 6th Conference on Thermal Power Plants (CTPP), 2016, pp. 1–5, doi: 10.1109/CTPP.2016.7482925.

[12] M. Ghinaul Qalbi, B. Suharto, and S. Wuryanti, “Analisis Efektivitas Cooling tower Sebelum dan Sesudah Pergantian Filler Pack,” J. Surya Tek., vol. 11, no. 1, pp. 394–399, 2024.

[13] R. Rahman and A. Mursadin, “Analisis Kinerja Cooling tower Menggunakan Metode Range Dan Approach Di Pltu Asam-Asam,” Jtam Rotary, vol. 4, no. 2, p. 129, 2022, doi: 10.20527/jtam_rotary.v4i2.6411.

[14] R. M. G. C. Sinaga, S. F. Dina, and H. Darmadi, “Besarnya Laju Perpindahan Panas Pada Heat Exchanger Tipe PlateDengan Menggunakan Aliran Fluida Chiller Di Pt. Abc,” J. Mek. Instrumentasi List. dan Otomasi, vol. 1, no. 1, pp. 15–25, 2024.

[15] E. Novianarenti and G. Setyono, “Peningkatan Performansi Cooling tower Tipe Induced Draft Counter Flow Menggunakan Variasi Bentuk Filler,” R.E.M (Rekayasa Energi Manufaktur) J., vol. 4, no. 1, 2019, doi: 10.21070/r.e.m.v4i1.1766.

Published

2025-12-30

How to Cite

Purba, J. H., & Syaputri, A. (2025). ANALISIS PERFORMA COOLING TOWER JENIS INDUCED DRAFT COUNTER FLOW DI POWER PLANT . Jurnal Teknologi Dan Riset Terapan (JATRA), 7(2), 51–58. https://doi.org/10.30871/jatra.v7i2.10911